Installation, Fan wiring – Regency Energy E18 Small Gas Insert User Manual

Page 42

Advertising
background image

42

Regency

®

E18 Gas Fireplace Insert

INSTALLATION

7a. Basic or FireGenie remote : Attach the other black wire from the

remote receiver to TH on the valve, see Diagram 7.

7b. GT remote control: Attach the green wire from the wiring harness

labeled TH and attach wire to TH on the valve, see Diagram 7.

8. Tuck all wires neatly into base of the unit.

9. Locate the red and black ON/OFF switch wires from the appliance,

see Diagram 8.

10. Locate the ON/OFF switch, packed in the manual package.

11. Connect ON/OFF switch wires to ON/OFF switch, see Diagram 9.

12. Snap ON/OFF switch into position.
Note: Ensure when snapped into position—the empty
terminal on the back side of the switch is facing upward, see Diagram 9.

13. Code remote control. See remote control manual for coding instruc-

tions and battery installation.

Important Note: When remote control is coded, ensure that the ON/OFF

switch is in the on position or facing up and the remote

receiver is in the remote position.

Diagram 7

Diagram 8

Diagram 9

WHITE

WHITE

GREEN

BLACK

ROTARY SPEED CONTROL

THERMODISC

RED

BLACK

BLACK

BLACK

HI LIMIT
SWITCH

SPILL
SWITCH

2 WAY
SWITCH

REMOTE CONTROL/WALL THERMOSTAT

TO TH - TP

ON VALVE

F/M

TO TH

ON VALVE

VALVE WIRING

F=Female
M=Male

CAUTION: Label all wires prior
to disconnection when servicing
controls. Wiring errors can
cause improper and dangerous
operation.

WARNING: Electrical Grounding Instructions

This appliance is equipped with a three pronged
(grounding) plug for your protection against shock
hazard and should be plugged directly into a prop-
erly grounded three-prong receptacle. Do not cut
or remove the grounding prong from this plug.

FAN WIRING

Empty terminal

ON/OFF switch wires

ON/OFF switch wires

Advertising