Installation – Regency Energy E18 Small Gas Insert User Manual
Page 26

26
Regency
®
E18 Gas Fireplace Insert
INSTALLATION
B
28-F / 28F-2 Firebox
E18 Insert
DETAIL B
SCALE 1 : 4
Adaptor Plate
fastener setting
2 5/8"
66mm
Flex Adaptor Length
Collar Plate Setting / Vent position
7 3/16"
183mm
6 1/16"
155mm
1 1/2"
39mm
A
28-F / 28F-2 Firebox
Le
E18 INSTALL SPECIFICATIONS
See Installation of E18 into Existing Units for General Installation Guidance for Vent Confi guration.
This install of the E18 uses Vent Connection Type A.
The Length of 4" Flex needed is 2-5/8" semi-expanded. Secure fl ue adapter top plate to under side of existing fi rebox using 4 self taping
screws.
28 F / 28 F2 INSTALLATION SPECIFICATIONS
1. Loosen 2 x philips screws on both right and left legs.
2. See above diagram below for required leg setting.
3. Install with supplied phillips screws to prepunched holes and tighten previous screws that were loos-
ened in Step 1.
4. Keep left side leg loose until outer fi rebox is in position in ZC box - to allow adjustment of gas line.
Right side shown
Set to this
hole
Set to this
hole
Secure top plate to fi rebox w/4 screws.
Secure vent slide plate to fl ex pipe with 4
screws