26

Regency

®

E18 Gas Fireplace Insert

INSTALLATION

B

28-F / 28F-2 Firebox

E18 Insert

DETAIL B

SCALE 1 : 4

Adaptor Plate
fastener setting

2 5/8"

66mm

Flex Adaptor Length

Collar Plate Setting / Vent position

7 3/16"

183mm

6 1/16"

155mm

1 1/2"

39mm

A

28-F / 28F-2 Firebox

Le

E18 INSTALL SPECIFICATIONS

See Installation of E18 into Existing Units for General Installation Guidance for Vent Confi guration.

This install of the E18 uses Vent Connection Type A.

The Length of 4" Flex needed is 2-5/8" semi-expanded. Secure fl ue adapter top plate to under side of existing fi rebox using 4 self taping

screws.

28 F / 28 F2 INSTALLATION SPECIFICATIONS

1. Loosen 2 x philips screws on both right and left legs.

2. See above diagram below for required leg setting.

3. Install with supplied phillips screws to prepunched holes and tighten previous screws that were loos-

ened in Step 1.

4. Keep left side leg loose until outer fi rebox is in position in ZC box - to allow adjustment of gas line.

Right side shown

Set to this

hole

Set to this

hole

Secure top plate to fi rebox w/4 screws.

Secure vent slide plate to fl ex pipe with 4

screws