Installation, Remote control installation – Regency Energy E18 Small Gas Insert User Manual

Page 41

Advertising
background image

Regency

®

E18 Gas Fireplace Insert

41

INSTALLATION

REMOTE CONTROL INSTALLATION

Remote controls approved for use with this appliance:

Part #

Remote

Function

910-368

Basic Remote

ON/OFF

910-399

Firegenie Remote

ON/OFF + 7 day programmable
thermostat

946-680

GT Profl ame Remote

ON/OFF + Thermostat control

NOTE: Remove bottom control panel on the surround prior to installing

the remote control.

1. S hut off gas and electrical supply, allow unit to cool to room temperature.

2. If using the GT Profl ame remote control, attach the wire labeled

receiver from the wiring harness to the back side of the remote
receiver. See Diagram 1 below.

Diagram 1

Diagram 4—cut female wire spade

Diagram 5

Diagram 6

Diagram 3 - Red TH wire disconnected

Diagram 2—Receiver in position

3. Install remote receiver (from any of the approved remote controls)

on the far right hand side of the unit. See Diagram 2 (Basic Remote
receiver shown).

4. Disconnect red wire from TH terminal on valve - see Diagram 3.

5. Cut the female wire spade from the disconnected red wire at the end

of connector see Diagram 4.

Bare the same red wire using wire strippers in order to connect new

male connector, see Diagram 4.

5a. Crimp on new male connector wire using a crimping tool, see Diagram 5.

6a. Basic or FireGenie remote: Attach one of the two black wires from

the remote receiver and connect it to the red wire disconnected in
the previous steps, see Diagram 5.

6b. GT remote control: Attach the white wire from the wiring harness

labeled TP/TH and connect it to the red wire disconnected in the
previous steps, see Diagram 6.

Receiver wire harness

GT remote

Female wire spade

Strip wire—add male

connector

Receiver

Advertising