Modes of operation – Rockwell Automation 22-SCM-232 Serial Converter Module User Manual

Page 14

Advertising
background image

1-6

Getting Started

Figure 1.4 Example Serial Connection to a Controller

Figure 1.5 Status Indicators on the Serial Converter Module

The serial converter module uses three status indicators to report its
operating status (

Figure 1.5

). The following table describes the state of

the status indicators under normal operation:

If the diamond status indicator is red, there is a problem. Refer to

Chapter 5

,

Troubleshooting

.

Serial

Converter

DSI Host

22-RJ45CBL-C20
Cable

1203-SFC
Cable

MicroLogix

Modes of Operation

#

Status Indicator State

Description

Diamond

Flashing Green Serial converter is connected to a product

implementing DSI.

Solid Green

Serial converter is or was receiving control
I/O. Removing or resetting the serial
converter may cause a serial fault in the
product.

Off

No power or Flash operation in progress.

TX

Off

Not transmitting data.

Flashing Green Transmitting data.

RX

Off

Not receiving data.

Flashing Green Receiving data.

AB

Advertising