A-2

Specifications

Important: For this product to be CE and CTick compliant, the shield

of the serial cable and DSI cable must be terminated as
described on

Page 2-2

.

Environmental

Temperature

Operating
Storage

0 to +50

° C (32 to 122° F)

-40 to +85

° C (-40 to 185° F)

Relative Humidity

5 to 95% non-condensing

Atmosphere

Important: Serial converter module must not be
installed in an area where the ambient
atmosphere contains volatile or corrosive gas,
vapors or dust. If the module is not going to be
installed for a period of time, it must be stored in
an area where it will not be exposed to a corrosive
atmosphere.

Vibration

Operating
Non-Operating

2.5G @5Hz-2KHz
5G @5Hz-2KHz

Shock

Operating
Non-Operating

30 G peak acceleration, 11 (±1) ms pulse width
50 G peak acceleration, 11 (±1) ms pulse width

Agency Certification

UL
cUL
CE

UL508C
CAN/CSA C22.2 No. 14-M91
EN50178 and EN61800-3

CTick

AS/NZS 2064, Group 1, Class A