B-2

Serial Converter Module Parameters

No.

Name and Description

Details

05

[Reset Module]
No action if set to “Ready.” Resets the serial converter
module if set to “Reset Module.” Restores the module
to its factory-default settings if set to “Set Defaults.”
This parameter is a command. It will be reset to “0 =
Ready” after the command has been performed.

Default:

0 = Ready

Values:

0 = Ready
1 = Reset Module
2 = Set Defaults

Type:

Read/Write

06

[Clear DF1 Counts]
No action if set to “Ready.” Resets the DF1 statistical
parameters (numbers 07 – 15) to 0 if set to “Clear
Counts.” This parameter is a command. It will be reset
to “0 = Ready” after the command has been
performed.

Default:

0 = Ready

Values:

0 = Ready
1 = Clear Counts

Type:

Read/Write

Reset Required: No

07

[DF1 Packets Sent]
Displays the number of DF1 packets sent by the serial
converter module. The value of this parameter is
normally approximately equal to the value of
Parameter 08 - [DF1 Packets Rcvd].

Default:

0

Minimum:

0

Maximum:

4294967295

Type:

Read Only

08

[DF1 Packets Rcvd]
Displays the number of DF1 packets received by the
serial converter module. The value of this parameter is
normally approximately equal to the value of
Parameter 07 - [DF1 Packets Sent].

Default:

0

Minimum:

0

Maximum:

4294967295

Type:

Read Only

09

[Undelivered Msgs]

(1)

Displays the number of DF1 messages that were sent
but not acknowledged.

Default:

0

Minimum:

0

Maximum:

65535

Type:

Read Only

10

[ENQs Sent]

(1)

Displays the number of ENQ characters sent by the
serial converter module.

Default:

0

Minimum:

0

Maximum:

65535

Type:

Read Only

11

[ENQs Received]

(1)

Displays the number of ENQ characters received by
the serial converter module.

Default:

0

Minimum:

0

Maximum:

65535

Type:

Read Only

12

[NAKs Received]

(1)

Displays the number of NAK characters received by
the serial converter module.

Default:

0

Minimum:

0

Maximum:

65535

Type:

Read Only

13

[NAK Bad Packet]

(1)

Displays the number of NAKs sent by the serial
converter module because of corrupt packets
(improper protocol messages) as determined by the
module.

Default:

0

Minimum:

0

Maximum:

65535

Type:

Read Only

(1)

This value is normally a low value. If it is continually incrementing and you are having
communications problems, use a lower baud rate or replace the 1203-SFC serial cable.

!

ATTENTION: Risk of injury or equipment damage exists. If the serial
converter module is transmitting I/O that controls the drive (indicated by a
solid green diamond LED), the drive may fault when you remove or reset the
module. Determine how your drive will respond before removing or resetting
a connected serial converter module.

Advertising