ControlLogix/CompactLogix Example Ladder Program

H-5

The data table used by the example ladder program is explained below:

Figure H.2 ControlLogix Ladder Example Data Table Values

Tag Name

Description

Example
Value
(decimal)

Example Value Description

Constant_0

Constant “0”

0

Fixed to “0” and used to
clear read data on the first
scan of the ladder program

DriveReadData[0]

Logic Status

1807

See Logic Status bit
descriptions (Appendix I)

DriveReadData[1]

Drive Error Code

0

No errors

DriveReadData[2]

Commanded Frequency

543

54.3 Hz

DriveReadData[3]

Output Frequency (feedback)

543

54.3 Hz

DriveReadData[4]

Output Current

1

0.01 A

DriveReadData[5]

DC Bus Voltage

3216

321.6 V

DriveReadData[6]

Output Voltage

2137

213.7 V

Logic_Command

Logic Command

18

See Logic Command bit
descriptions (Appendix I)

Reference

Speed Reference

543

54.3 Hz

Parameter39_RDValue

Pr. 39 - [Accel Time 1] Read Value 50

50.0 Seconds

Parameter39_WRValue Pr. 39 - [Accel Time 1] Write Value 50

50.0 Seconds