3-6
Programming and Parameters
Display Group
(continued)
d014 [Dig In Status]
Related Parameter(s):
Status of the control terminal block digital inputs.
Values
Default
Read Only
Min/Max:
0/1
Display:
1
1 = Input Present, 0 = Input Not Present
Digital In1 Sel (I/O Terminal 05)
Bit 0
Digital In2 Sel (I/O Terminal 06)
Bit 1
Reserved
Bit 2
Reserved
Bit 3
d015 [Comm Status]
Related Parameter(s):
Status of the communications ports.
Values
Default
Read Only
Min/Max:
0/1
Display:
1
1 = Condition True, 0 = Condition False
Receiving Data
Bit 0
Transmitting Data
Bit 1
RS485 (DSI) Based Option Connected
Bit 2
(Allen-Bradley devices only.)
Communication Error Occurred
Bit 3
d016 [Control SW Ver]
Main Control Board software version.
Values
Default
Read Only
Min/Max:
1.00/99.99
Display:
0.01
d017 [Drive Type]
Used by Rockwell Automation field service personnel.
Values
Default
Read Only
Min/Max:
1001/9999
Display:
1