Module Overview 1-3
Most programming parameters, except those in the Module Setup and
Counter Configuration blocks, are dynamic and can be changed
without halting counter operation. The table below lists the static and
dynamic parameters by programming block.
Programming Block
Parameter
Type
(1)
(1) STATIC = the associated counter must be disabled to set this parameter.
DYNAMIC = this parameter may be changed while the associated counter is running.
Module Setup
Operating Mode
Static
Range Allocation
Interrupt Enable
Rate Value Format
Counter Configuration
Counter Type
Static
(2)
Input Configuration
Gate/Preset Mode
Min./Max. Count Value
Minimum Count
Static
(2)
(2) Only the selected counter must be disabled.
Maximum Count
Static
(2)
Preset Value
Dynamic
(3)
(3) Under specific conditions, this parameter is dynamic. See page 4-15 for more information.
Min./Max. Rate Value
Minimum Rate
Dynamic
Maximum Rate
Program Range
Counter Number
Dynamic
Range Type
Range Number
Start Value
Stop Value
Output Image
Counter Control
Enabled
Dynamic
Soft Preset Only
Internal Direction
Output ON Mask
Output OFF Mask
Count or Rate Value
Range Enable Mask