Rockwell Automation 1746-HSCE2 Multi-Channel High Speed Counter Module User Manual
Page 79

Publication 1746-UM002B-EN-P - August 2004
Configuration and Programming 4-29
Table 4.12 Class 1, Mode 2 Default Values
Parameter
Counter 1
Counter 2
Counter 3
Debug Mode Selection
Inactive
Range Allocation
8
4
4
Counter Type
Ring
Ring
Ring
Input Configuration
X1 Quadrature
Pulse/Internal
Pulse/Internal
Gate/Preset Mode
Store/Preset/Start
No Preset
No Preset
Minimum Count
-32,767
-32,767
-32,767
Maximum Count
+32,767
+32,767
+32,767
Minimum Rate
-32,767
-32,767
-32,767
Maximum Rate
+32,767
+32,767
+32,767
Preset Value
0
0
0
All Output Ranges
Not programmed.
Interrupt Enable
Interrupt disabled
Rate Value Format
Integer (not programmable)
Table 4.13 Class 1, Mode 3 Default Values
Parameter
Counter 1
Counter 2
Counter 3
Counter 4
Debug Mode Selection
Inactive
Range Allocation
4
4
4
4
Counter Type
Ring
Ring
Ring
Ring
Input Configuration
Pulse/Internal
Pulse/Internal
Pulse/Internal
Pulse/Internal
Gate/Preset Mode
No Preset
No Preset
No Preset
No Preset
Minimum Count
-32,767
-32,767
-32,767
-32,767
Maximum Count
+32,767
+32,767
+32,767
+32,767
Minimum Rate
-32,767
-32,767
-32,767
-32,767
Maximum Rate
+32,767
+32,767
+32,767
+32,767
Preset Value
0
0
0
0
All Output Ranges
Not programmed.
Interrupt Enable
Interrupt disabled
Rate Value Format
Integer (not programmable)