Programming block default values, Programming block default values -28, Class 1 -28 – Rockwell Automation 1746-HSCE2 Multi-Channel High Speed Counter Module User Manual
Page 78: Class 1

Publication 1746-UM002B-EN-P - August 2004
4-28 Configuration and Programming
Programming Block Default
Values
The following tables list the default values for all of the programmed
parameters in each class and operating mode. The default operating
mode for each class is mode 1.
Class 1
Figure 4.10 Determining Actual Outputs
Range Bit Setting
1
1
0
0
1
1
0
0
Output ON Mask
0
0
0
1
0
0
0
1
Output Enable Mask
0
0
0
0
1
1
1
1
Actual Outputs
0
0
0
0
1
1
0
1
Table 4.11 Class 1, Mode 1 Default Values
Parameter
Counter 1
Counter 2
Debug Mode Selection
Inactive
Range Allocation
8
8
Counter Type
Ring
Ring
Input Configuration
X1 Quadrature
X1 Quadrature
Gate/Preset Mode
Store/Preset/Start
Store/Preset/Start
Minimum Count
-32,767
-32,767
Maximum Count
+32,767
+32,767
Minimum Rate
-32,767
-32,767
Maximum Rate
+32,767
+32,767
Preset Value
0
0
All Output Ranges
Not programmed.
Interrupt Enable
Interrupt disabled
Rate Value Format
Integer (not programmable)