DeviceLogix for POINT I/O and ArmorPOINT I/O on DeviceNet 35

The digital modules can be found under the category, “General Purpose
Discrete I/O”, and the analog modules can be found under the “Rockwell
Automation miscellaneous” category.

The configuration of each module can now be edited from the Properties
dialog box of each module. For instructions on editing the configuration of the
DeviceLogix module, see

Chapter 6

.

Include all the I/O modules in the backplane to the Scanner’s scan list.

After configuration is complete, save your work in the DNT file. “DNT” is
the three-letter file name extension. One file contains all the configuration data
for all the modules on the network or backplane.

Remember that you need to go to the Online mode with RSNetWorx for
DeviceNet to download all the configuration data to the I/O modules and
scanners.