78 DeviceLogix Capabilities
Offline and Online Editing
Editing of the configuration and DeviceLogix program can be done off-line
and saved in the DNT file created by RSnetWorx for DeviceNet. The changes,
however, must be manually downloaded to the module while online. When
using RSLogix 5000 with an EtherNet/IP or ControlNet adapter, the forward
open to the DeviceLogix module does not contain any configuration
information. The configuration must be sent via RSNetWorx for DeviceNet
while online.
The I/O module will save the configuration and DeviceLogix program locally
(inside the module). You will only need to download the configuration once. If
you replace the device, you need to download the configuration to the new
module.
Before the DeviceLogix program executes, it must be enabled. You can do this
using the Editor while online. For details, see
Alternatively, you can use the owning processor to enable the program. For
details, see
.
DNT File
RSNetWorx for DeviceNet
Online
Module