Panel Mounting Guidelines
Observe these guidelines when installing the unit in a panel:
•
Confirm that there is adequate space within the panel enclosure.
•
Cut supporting panels to specifications before installation. Take
precautions so metal cuttings do not enter components already
installed in panel.
•
Supporting panels must be at least 14 gauge to be sure of proper
sealing against water and dust and to provide proper support.
The mounting hardware supplied accommodates panels up to
6.25 mm (0.25 in.) thick.
Panel Cutout Dimensions
ATTENTION
Failure to follow these guidelines may result in personal injury
or damage to the panel components.
Workstation Model
Cutout Dimensions (HxW), approx.
1200W
279.0 x 450.0 mm (10.98 x 17.72 in.)
1500W, Non-display
326.4 x 429.3 mm (12.85 x 16.90 in.)