Installation 23

6. Gradually tighten the clips, one at a time, around the bezel by

following the specified sequence.

The sequence begins with the center clips and continues to the
corner clips. Repeat this process at least three times until the
clips are hand-tight and the gasket is compressed uniformly
against the panel.

7. Tighten the mounting clips to a torque of 1.4 Nm (12 lb-in)

using the sequence in step 6, being sure not to overtighten.

Mount the Non-display
Workstation in a Panel

The non-display workstation mounts on a wall, panel, or 19-inch rack.
The workstation attaches to the panel using the four screw slots in the
front plate. Use M5 or #10 screws (or larger). Screws are not included.

ATTENTION

Tighten the mounting clips to the specified torque to provide a
proper seal and prevent damage to the product. Rockwell
Automation assumes no responsibility for water or chemical
damage to the product or other equipment within the enclosure
because of improper installation.

1

10

9

2

7

8

5

4

11

6

Torque Sequence for 1500W

3

12

1

8

7

2

5

6

3

9

4

Torque Sequence for 1200W

10

ATTENTION

Remove all electrical power from the panel before making the
cutout. Make sure the area around the panel cutout is clear. Do
not allow metal cuttings to enter components that are already
installed in the panel. Failure to follow these warnings may
result in personal injury or damage to the panel components.

465.30 mm (18.33 in.)

279.