Rockwell Automation 6180W-xxxx VersaView Workstation User Manual User Manual
Page 60

Publication 6180W-UM001H-EN-P - August 2007
60 Specifications
Environmental Specifications
Attribute
Value
Temperature, operating
0…50 °C (32…122 °F)
Temperature, storage
-20…60 °C (-4…140 °F)
Relative humidity, operating
(1)
(1)
Derate above 40 °C to 45% at 50 °C.
20…85% without condensation
Relative humidity, nonoperating
(2)
(2)
Derate above 40 °C to 39% at 60 °C.
5…90% without condensation
Vibration, operating
0.006 in. p-p, (10…57 Hz); 1 g peak (57…500 Hz)
Vibration, nonoperating
0.012 in. p-p, (10…57 Hz); 2 g peak, (57…500 Hz)
Shock, operating
15 g (1/2 sine, 11 ms)
Shock, nonoperating
30 g (1/2 sine, 11 ms)
Enclosure ratings, panel mounted
NEMA Type 4, 12, IEC IP66
Certifications
(1)
(1)
Se
Attribute
Value
c-UL-us
UL 60950 recognized component, c-UL 950
recognized component, or UL/c-UL listed when
marked
CE
Marked for all applicative directives
LVD (72/23/EEC)
EMC (89/336/EEC)
C-Tick
Australian Radiocommunications Act, compliant
with: AS/NZS CISPR 11; Industrial Emissions
RoHS compliant