Publication 999-126 - February 1996

Installation & Hook-Up

23

The relay output can be used to disable external devices or
incorporated into your machine’s E-stop string (or other protective
circuitry) for fail-safe protection. The REC provides Form_C
(Normally Open) contacts to disable external equipment in the event
of a malfunction.

Important: Both the fault relay and the LED (Axis OK) are

activated during normal operation and deactivated during
a malfunction.

The fault output relay contacts are UL listed and CSA certified for 1A
at 30V DC. Figures 2.13 and 2.14 are examples of typical fault relays.

Figure 2.13
A typical Normally Open Fault status contact

24V DC

11

1

CR1

CR1

Start/Stop String

Fault String

Start

REC Fault contact

located at Axis 0,1

Resolver connector

Stop

DC

Common