Transferring Via the Data Highway Plus

Chapter 4

and Remote I/O

4-11

c

Enter the drive and directory that contains the Pass-Through utility.
By default this is C:\AB\PB1200\PTU\PASSTHRU.

3

When you have finished configuring the computer, choose Quit.

Completing the Download

Once you have configured the parameters on the PanelView 1200 terminal
and on your computer, and have established the PanelView location data,
you’re ready to begin downloading.

If your PanelView 1200 terminal’s Address Source is Manual, ensure that
the terminal is communicating with the PLC controller. The message “PLC
communication lost” should not appear on the terminal when it is in Run
mode.

Important

Don’t try to download application files from two development

computers to the same location via the Pass-Through at the same time.
Results are unpredictable. The first download will be terminated, but the
second download may or may not be completed successfully.

Note

The PanelView 1200 terminal ignores all operator and PLC inputs

and outputs during the download. The rack assignments and PLC status
will remain as per the previous application until the download is complete.

To initiate the download:

1

Ensure that both the PLC controller and the PanelView 1200 terminal
are active on the network and in RUN mode.

2

Choose Download Application File from the Pass-Through Download to
PanelView (DH+ and Remote I/O) menu.

A message appears, warning you that the addressing information which
locates the PanelView 1200 terminal on the network must be correct.

Attention

Incorrect address selection could corrupt data in a

non-PanelView 1200 device. Verify that the address entered is
correct for your network.

3

If you are sure of your settings, choose Continue.

A further prompt will display the estimated time for the download.

4

Choose Start Downloading to start the download.