Rockwell Automation 2711 PanelBuilder 1200 Transfer Utility User Manual

Page 42

Advertising
background image

Transferring Via the Data Highway Plus

Chapter 4

and Remote I/O

4-16

2

Configure the parameters as follows:

a

Enter a value (0–77 octal) for the Programming Terminal DH+
Address.

b

Choose DH+ Hardware Driver, select the appropriate driver, and
configure it as required.

c

Enter the drive and directory that contains the Pass-Through utility.
By default this is C:\AB\PB1200\PTU\PASSTHRU.

3

When you have finished configuring the computer, choose Quit.

You’re back at the Pass-Through Upload from PanelView menu.

Completing the Upload

After you’ve configured the computer’s communications and the
PanelView location data, you can upload the application file.

Important

Be sure that you are not about to overwrite a file on the

application computer’s hard disk which is more recent than the file in the
terminal.

To upload the application file:

1

Ensure that the PanelView 1200 terminal and the PLC-5 are active on
the network.

2

Choose Start Upload in the Pass-Through Upload From PanelView
menu.

Attention

Incorrect address selection could corrupt data in a

non-PanelView 1200 device. Before starting the upload, verify
that the address entered is correct for your network.

3

If you are sure of your settings, choose Continue.

As the upload begins, the Start Upload menu displays information about
the application file in the terminal, and the destination of the application
file on the development computer’s disk.

Advertising