To burn a single EPROM for Series D, E and F terminals:

1

Connect your computer to an EPROM burner with an RS-232 serial
cable.

The EPROM burner is connected to the same RS-232 port on the
development computer that is used to connect the PanelView 1200
terminal. Refer to your EPROM burner user’s manual for connection
instructions.

2

Start the PanelView 1200 Transfer Utility.

3

Open the Transfer menu.

4

Choose Burn Single EPROM from the Transfer menu.

5

Choose Select Application File and select the application you want to
download to the EPROM burner. Press

ENTER

.

If the file is greater than 64K, a warning message appears: “This
application exceeds the memory limit (64K) for hex files or PROMs.
Delete one or more objects, messages, or screens to reduce size to 64K
or less”.

PanelBuilder takes a few seconds to generate the hex file. When the file
is created, a message appears, informing you that the hex files have been
generated successfully. The Burn FILENAME menu opens, (where
FILENAME is the name of the application you selected).

23625

MAIN MENU:

Screens

Windows

Options

Communic

Exit

Transfer

Download to PanelView (RS-232)

Upload from PanelView (RS-232)

Pass-Through Download to PanelView (DH+ and Remote I/O)

Pass-Through Upload from PanelView (DH+ and Remote I/O)

Burn EPROMS

Burn Single EPROM

Quit

Burn Single EPROM

Select Application File

EXAMPLE

Select Hex File

EXAMPLE

Generate Hex Files

EXAMPLE

Directory

Quit

Burn EXAMPLE

Send User Memory [U2]

Configure Port

COM1

Application Size

Quit

Advertising