Transferring Via the Data Highway Plus

Chapter 4

and Remote I/O

4-14

Or you can define each field manually:

Rack—Specify the rack where the address is located. The number you

can enter depends on the PLC controller you’re using.

Group—Specify the group within the specified rack where the address

is located.

Module—Specify whether the address occupies the High or Low byte.

PLC Type—Specify the PLC controller you’re using.

PLC DH+ Address—This address defines the address of the PLC

controller on the Data Highway Plus. You must enter a value between
0–77 (octal).

Local Bridge Address—Define this field only if you have two Data

Highway Plus networks joined by a connecting module or “bridge”.
Enter a value between 0–77 (octal).

Remote Bridge Address—Define this field only if you have two Data

Highway Plus networks joined by a connecting module or “bridge”.
Enter a value between 0–376 (octal).

To load the PanelView location data:

1

If you want to load the application’s data, choose Load PanelView
Location Data in the Pass-Through Upload From PanelView menu.

The Load PanelView Location Data window appears.

22585

Load PanelView Location Data

Select Application File

No File Selected

Application File Comment

Select DirectoryC: \AB\PB1200

Quit

a

Choose Select Application File, and select the application file whose
PanelView location data you want to use.

b

If you need to change the directory to find the application you want,
choose Select Directory, and enter a new directory. Then choose the
application file.

c

Choose Quit.