Installing the Converter

2-3

PowerFlex 1203-USB Converter User Manual

Publication DRIVES-UM001D-EN-P

Connecting the Converter to a DSI Drive and the Computer

Use the 22-HIM-H10 cable to connect the converter to a DSI drive. Use the
USB cable to connect the converter to the computer.

Important: The 22-HIM-H10 cable shield must be properly grounded to

provide EMC protection. For example, terminal 16 on a
PowerFlex 4-Class drive and terminal C1 on a PowerFlex
520-Series drive should be connected to the drive earth ground.
See the respective drive User Manual for additional
information.

1. Connect the 22-HIM-H10 cable (required for PowerFlex drives) or the

2090-CCMUSDS-48AA0x cable (required for Kinetix 3 drives)
between the converter and the DSI drive.

2. Connect the USB cable between the converter and the computer.

22-HIM-H10 Cable

(for PowerFlex drives)

USB Cable

2090-CCMUSDS-48AA0x Cable

(for Kinetix 3 drives and ordered separately)

22-HIM-H10 Cable