Use with HyperTerminal Software

E-7

PowerFlex 1203-USB Converter User Manual

Publication DRIVES-UM001D-EN-P

Viewing and Clearing DF1 Communication Statistics

If you encounter unexpected communications problems or are creating an
application that uses DF1 data, you can view the communications statistics
stored in the converter.

To view and clear DF1 data, you must access the main menu in the
1203-USB converter firmware.

Viewing DF1 Data

1. Access the parameters in the 1203-USB converter using HyperTerminal

software.

2. View converter parameters Parameters 04 - [DF1 Packets Sent] and

05 - [DF1 Packets Rcvd], which store DF1 data.

See the following pages for a description of each parameter:

Parameters – DPI Drives on page B-1

Parameters – DSI Drives on page B-2

Parameters – SCANport Drives (DriveExplorer or DriveExecutive
software only) on page B-4

Clearing DF1 Data Counters

1. Access the parameters in the 1203-USB converter using HyperTerminal

software.

2. View converter Parameter 03 - [Clear DF1 Counts].

3. Set its value to Clear Counts.

4. Press Enter to clear the DF1 data.

Press the UP ARROW or DOWN ARROW key to scroll

through the parameter list. Press the LEFT ARROW

or RIGHT ARROW key to modify parameter values.

Press the ENTER key to save a new value.

4R> DF1 Packets Sent = 0

Press the UP ARROW or DOWN ARROW key to scroll

through the parameter list. Press the LEFT ARROW

or RIGHT ARROW key to modify parameter values.

Press the ENTER key to save a new value.

3> Clear DF1 Counts = Clear Counts