D-4

Use with DriveExecutive Software

PowerFlex 1203-USB Converter User Manual

Publication DRIVES-UM001D-EN-P

9. Enter the following settings.

10. Click OK.

The Configure Drivers dialog box appears.

11. Verify that the status of the newly created driver is ‘Running’.

12. Click Close.

13. From the Communications menu, choose RSWho to display the browse

window.

14. Expand the treeview in the left pane to display the ‘DPI’ or ‘DSI’ icon

to verify that the driver is communicating with the device.

The browse window should look similar to this example window.

Configuration Field

Setting

Comm Port

Select the same COM port established during installation of the

1203-USB driver (noted in step 1 on

page D-2

). For this example,

COM5 is used.

Device

1770-KF2/1785-KE/SCANport

Baud Rate

115200

Station Number

00 (default)

Parity

None (default)

Error Checking

BCC (default)

Stop Bits

1 (default)

Protocol

Full Duplex (default)