Rockwell Automation 1203-USB Converter User Manual
Page 67

Use with DriveExplorer Software
C-3
PowerFlex 1203-USB Converter User Manual
Publication DRIVES-UM001D-EN-P
Important: DriveExplorer software has its own drivers. If a driver has
been configured using RSLinx software for that same COM
port, it must be deleted with RSLinx software before
DriveExplorer is launched.
3. If not already running, launch DriveExplorer Lite software (or the full
version of DriveExplorer software).
4. From the Explore menu, choose Configure Communication.
5. Select the COM port noted in step 1 and a baud rate of ‘115200’.
6. Select either checksum, and accept the default time for the Comm
Timeout.
7. Click OK.
8. Choose Explore > Connect > Serial Point-to-Point.
A node eventually appears in the DriveExplorer window under Devices
in the treeview.
9. In the left pane, click the Parameter List for the 1203-USB converter or
connected drive to display its parameters in the right pane.
10. Double-click a parameter to edit it.