Configuring rslinx for serial multi-drop system – Rockwell Automation 1203-USB Converter User Manual
Page 44
Advertising
3-12
Configuring the Converter
PowerFlex 1203-USB Converter User Manual
Publication DRIVES-UM001D-EN-P
Configuring RSLinx for Serial Multi-Drop System
The Configured Driver in RSLinx is slightly different when configuring for
a RS-485 multi-drop system as opposed to a point-to-point system (single
drive).
1. Open RSLinx software.
2. From the Communications menu, choose Configure Drivers.
3. From the Available Driver Types pull-down menu, choose RS-232 DF1
devices.
4. Click Add New and enter a name.
5. Enter all settings as shown in the following image.
The Comm Port address will vary depending on the port that gets
assigned to the 1203-USB converter. In this example, the 1203-USB
converter is connected to COM3.
Advertising