Installation and mechanical alignment, 3 model macn-1 controller hookup, 4 model macv-1 controller hookup – Banner A-GAGE MINI-ARRAY Series User Manual

Page 16: Mini-array, Output 1, Alarm, Voltage outputs 1 and 2, Instruction manual

Advertising
background image

16

P/N 43298 rev. E

Banner Engineering Corp.

Minneapolis, MN U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

MINI-ARRAY

®

Instruction Manual

Installation and Mechanical Alignment

1

+

+

10-30V dc

Gate

16-30V dc

1.2 A Max.

2

3

4

5

6

7

8

9

10

13

14

15

F1

BROWN

BLUE

DRAIN (BARE)

BLACK

WHITE

EMITTER and

RECEIVER CABLES

V-

V+

RS485

Out 1

30V

150 mA

Max.

30V

150 mA

Max.

ALARM

Power

12

11

Com

1

+

10-30V dc

Gate

16-30V dc

1.2 A Max.

2

3

4

5

6

7

8

9

10

13

14

15

F1

BROWN

BLUE

DRAIN (BARE)

BLACK

WHITE

EMITTER and

RECEIVER CABLES

V-

V+

30V

150 mA

Max.

ALARM

0-10V

10 mA

V out 2

Power

12

11

Com

Com

0-10V

10 mA

Max.

V out 1

Figure 3-7. Model MACN-1 hookup

Figure 3-8. Model MACV-1 hookup

3.4.3 Model MACN-1 Controller Hookup

Output 1:

Controller terminal #9 (OUT1) is an open-collector NPN transistor switch

rated at 30V dc max., 150 mA max. It is protected against overload and short circuits.

Alarm:

Controller terminal #15 (ALARM) is an open-collector NPN transistor switch

rated at 30V dc max., 150 mA max. It is protected against overload and short circuits.
Both outputs are current sinking.

3.4.4 Model MACV-1 Controller Hookup

Voltage outputs 1 and 2:

Controller terminals #9 (V out 1) and #13 (V out 2) are

analog voltage outputs. The load for analog voltage Output #1 should be tied across

terminals #9 and #10. The load for analog voltage Output #2 should be tied across

terminals 13 and 14. Both switches are rated at 10V dc max., 10 mA max. Both

outputs are voltage sourcing.

Alarm:

Controller terminal #15 (ALARM) is an open-collector NPN transistor rated at

30V dc max., 150 mA max., current sinking.