System operation, 3 diagnostics program – Banner A-GAGE MINI-ARRAY Series User Manual

Page 37

Advertising
background image

P/N 43298 rev. E

37

Banner Engineering Corp.

Minneapolis, MN U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

MINI-ARRAY

®

Instruction Manual

System Operation

6.3 Diagnostics Program

Emitter or receiver problems may be further diagnosed using the diagnostics routine,

which is included with the MINI-ARRAY software. Launch the program by selecting

Diagnostics... under the MINI-ARRAY menu (see Figure 6-3), or press the

F2

key.

The Diagnostics screen (Figure 6-4) displays the type of each emitter and receiver

module (Board) and its functional status (State). If an error has occurred, the specific

problem beam (Channel) will be identified. Additionally, If there is a problem with an

emitter or receiver cable connection, a “No Response” message will be displayed.
The Diagnostics routine also displays the part number and date code of the controller,

which may be useful information if factory-assisted troubleshooting by telephone is

required.

Figure 6-3. MINI-ARRAY software: Main Menu

Figure 6-4. MINI-ARRAY software: Diagnostics screen