MINI-ARRAY

®

Instruction Manual

Figure 5-20. Serial communication

options

Figure 5-19. MINI-ARRAY software: Serial

Communication Parameter
selection

5.5.6 Control Mode Selection

The controller can be programmed for Continuous scanning, Gated scanning, or for

Host mode. The module offers an optically-isolated

Gate

input, which is energized

by application of 10 to 30V dc. Gating is typically accomplished using a dc presence

sensing device.

Host mode

allows the array to be gated by a host computer or

programmable logic controller (PLC).

Host Control

All MINI-ARRAY Systems can communicate with a host computer or controller via RS-

232 serial protocol. In addition, controller models MAC-1, MACN-1, and MACP-1 also

can communicate via RS-485. The host can direct the MINI-ARRAY System to scan on

demand and/or receive the scan data directly from the MINI-ARRAY System in binary

or ASCII form. Selectable communication baud rates are 9600, 19200, and 38400.

5.6 Serial Communication

The MINI-ARRAY System can communicate with its host computer or controller via

either RS-232 (all models) or RS-485 (MAC-1, MACN-1, MACP-1) serial protocol.

The host can direct the MINI-ARRAY to scan on demand, and/or receive the scan

data directly from the MINI-ARRAY System in Binary or ASCII form, Selectable

communication baud rates are 9600, 12000, and 38400 (Figure 5-19). Protocol is

one start bit, one stop bit, 8 data bits, and even parity. See the Appendix for more

information on data formats.
When RS-485 communication is used, each controller module may be assigned

a controller ID. Select letter A through O for individual identification of up to 15

Controllers on a RS-485 “party line.”

5.6.1 Serial Transmission

Serial Transmission activates the serial port, specifies the data format, and provides

data suppression options. If No Serial Communication is selected (default), the serial

port does not transmit sensing data. See Figure 5-20.
ASCII Transmission specifies that the scan data will use the ASCII format. ASCII

Transmission has one suppression option called Suppress Clear Data, which means

that data is sent one time when the array is completely clear (i.e., when no beams are

blocked) and no further data is sent until one or more beams are blocked.
Binary Transmission specifies that the scan data will use the binary format. The binary

format has three suppression options. The first option is Suppress Clear Data, which

means that data is sent once when the array is completely clear (i.e., when no beams

are blocked), and no further data is sent until one or more beams are blocked. The

Suppress Header option reduces the size of the controller serial message by three

bytes. Header bytes consist of the two byte start string plus the termination byte. The

Compress Data option, in many cases, reduces the number of data bytes sent for each

analysis mode from two to one byte.
See the Appendix for additional information.

Figure 5-18. MINI-ARRAY software:

control mode selection

Controller Configuration