Controller configuration, 1 communications setup, 2 alignment analysis – Banner A-GAGE MINI-ARRAY Series User Manual

Page 20

Advertising
background image

20

P/N 43298 rev. E

Banner Engineering Corp.

Minneapolis, MN U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

MINI-ARRAY

®

Instruction Manual

Configuration of the MINI-ARRAY controller is accomplished with a Windows

®

menu-

style procedure, using the Banner-supplied software and a PC-compatible computer
running Windows

®

XP, Vista, or 7.

A serial data connection is made

between the computer and the DB9 connector on the controller (see Figure 3-12).
Parameter Setup Files (PSF) are programmed configurations that can be stored in the

control module’s non-volatile memory. The Banner software can store various PSFs in

computer files for instant call-up of a particular configuration.
The Banner software also provides two additional features: An Alignment screen and a

Diagnostics screen

5.1 Communications Setup

The MINI-ARRAY software permits serial communication via RS-232 between the MAC

controller and the PC. The minimum connections to the DB-9 connector on the

MINI-ARRAY Controllers are as follows:

Figure 5-1. MINI-ARRAY software Option

menu

Figure 5-2. MINI-ARRAY software Main

menu

NOTE:

DO NOT

use a “null modem” RS-232 cable.

Configure the COM port of the PC by first selecting the

Options

menu (see Figure

5-1). The program supports serial communication via

the.COM1-COM20.port.

of the computer. Select

Options

, then select

Serial Port

(or

Enter

). Select either

COM1

or

COM2

. Check

Save

Settings on Exit

(if it is not already checked) to store

the COM port selection.

5.2 Alignment Analysis

Alignment status is continuously displayed by the green LED indicator on the Receiver

and the controller. When all unblanked beams are clear, and excess gain of all beams

is more than 3x, the green alignment indicators will be ON. When the excess gain

of one or more beams drops to between 3x and 1x, the green

ALIGN

LED on the

controller will remain ON, but the yellow LED on the receiver will come ON to indicate

a warning of marginal alignment. See Section 6 for more information about sensor

alignment.
One feature of the MINI-ARRAY software is a program that displays the status of

each beam in the array. This routine can be very helpful for final alignment or when

analyzing how the MINI-ARRAY is viewing objects in the sensing array. To launch this

program, select

Alignment...

under the

MINI-ARRAY

menu (see Figure 5-2), or

press the F3 key.

Controller Configuration

5. Controller Configuration

Pin Number of DB-9

Function

2

Transmit (TX)

3

Receive (RX)

5

Ground (GND)

Advertising