Data Transfer Device Operating Instructions Section 3: DTD Mode

3.2.3 SET DOOR CLOCK

SoloPlus

TM

has an option to automatically set the time and date in the controller when you export. You also have the option to

manually set the time and date in the door controller using this menu option. First, enter your Comm Unlock code on the door
controller. Next aim your DTD at the Infrared (IR) port on the controller and press the ENTER key. If successful, the message below
is displayed on the DTD screen.

3.2.4 OPTIONS

The OPTIONS menu allows you to set the DTD to the following three options: EXPORT ONLY, IMPORT ONLY or IMPORT &
EXPORT. If you only wish to export data to the controller, choose EXPORT ONLY by pressing the ENTER key with the cursor next
to that option. When set, the DTD displays a confirmation message. Press the left arrow to exit the message and return to the menu.
The “=” symbol indicates which options is currently set. Select the IMPORT ONLY option when you only want to import transaction
log data from the door controller without exporting any data to it. The IMPORT & EXPORT options performs both operations.