Passport 1000 PG Cylindrical Lock

5 – Lock Installation

A. Lock Preset:

• Lock body holes – 12 & 6 o’clock (Fig. 5A).
• Door thickness – 1-3/4” thick. Refer to adjustments below for other door conditions (Fig. 5B).

B. Through bolt and Door Thickness Adjustment:

• Through bolt location: Rotate outside rose to match

door (Fig. 5B).

• Door thickness: Rotate outside rose to align

door thickness, marking with lock body edge.

• Spacer bushing: Remove and realign to fit

into back of lever.

C. Install Lock:

1. Feed wires into the lock body hole, from outside of door (Fig. 5C).
2. Slide lock body into cross-bore hole from outside (locked side)

of the door (Fig. 5D Detail).

3. Lock body must engage both the latch unit prongs and

tail piece (Fig. 5C).

IMPORTANT:
• Door must remain open during installation.

Use door stop.

• Lock body must be centered in the door.

Fig. 5C

Fig. 5A

Lock Body Holes

Spacer Bushing

Rotate to match

lock body holes in door.

Through Bolt Holes

Fig. 5B (Detail)

1-3/4” Thick Doors

2” Thick Doors

Fig. 5D (Detail)

Wire Harness
(From Lock Body)

Cylindrical Lock Body
and Outside Trim

Outside of Door