• Select closer mounting position based on the maximum door opening, as listed below
Note: For ADA applications, select the 180º position.
1
PARALLEL APPLICATION
• Using the enclosed self adhesive template, locate and mark hole locations
Note: 3/32" pilot holes are required when Self Tapping Screws are being used
If machine screws are being used, use a drill #16 (.177) and a #12-24 tap
2
• Install closer body onto the door with 5/8" power adjustment nut end towards hinge
• Install foot bracket & rod assembly onto the frames
3
Note: P9 or RP9 arm shown.
For P3, P3A, P4,P4A arms,
use data sheet enclosed
LEFT HAND DOOR SHOWN
SAME DIMENSIONS APPLY FOR RIGHT HAND DOOR
*SEE PAGE 8 FOR MORTISE NUTS