ELR 7000 Series Multi Point Lock

ELR- Input Requirements

Voltage: 24VDC
• Filtered and regulated power supply
• Motor operating current: 700mA
• Motor hold current: 150mA

Note: Earth Ground is required for Electrostatic

Discharge (ESD) protection unless the metal door

and frame are already earth grounded; otherwise,

earth ground wiring is required at pin 4

(Fig. 2 POWER MODE

Installation).

Stand Alone ELR

An ElectroLynx harness

is required to connect the

ElectroLynx hinge.

Note: Specified and

ordered separately

McKinney QC8 Electric

Hinge (with 8-pin connector)

Fig. 2 POWER MODE Installation

SIgNal

CauSE

TROuBlEShOOTINg

Dark / Unlit

Controller microprocessor

is not active

Confirm connections and incoming

power

Steady Flashing (GREEN)

Normal operation

Check that POWER MODE switch is set

Solid Light (GREEN)

Input voltage is dropping out of

operating range

Check wire run and power supply output

1 Flashes Followed by Pause (YELLOW)

Retractor sensor problem

Call 800-810-WIRE for assistance

2 Flashes Followed by Pause (YELLOW)

Retractor sensor problem

Call 800-810-WIRE for assistance

3 Flashes Followed by Pause (YELLOW)

Retractor sensor problem

Call 800-810-WIRE for assistance

2. LED Signalling Chart