ELR 7000 Series Multi Point Lock

3. POWER MODE Troubleshooting

Prior to electrical troubleshooting, confirm that the mechanical system properly functions; i.e., that the levers fully retract
all latches and the door opens freely. Refer to applicable Sargent 7000 Series Multi-point Device product instruction sheet to
correct mechanical installation issues.
IMPORTaNT: *ALWAYS disconnect power before making any mechanical adjustments to the system.

The push rail does not move when 24V/12V input is applied:

o Check inputs to confirm proper voltage and wiring orientation.

o Remove cover and confirm that LED is blinking steadily when power is applied. If not, refer to LED signaling.

Note: When configured in POWER MODE, power is released to lock the device (LED will not blink when power is released).

o Confirm all four DIP switches are in the UP position.

The ELR module does not fully retract or push rail retracts completely and holds but does not open door

o *Verify mechanical installation and correct as necessary:

- Is excessive force required to depress the push bar?

- Are latches fully clearing the strikes when mechanically cycled?

The ELR module retracts and unlocks electrically but does not relock:

o Physically disconnect power from rail and confirm that input is off.

o *Check for mechanical interference (e.g., warped door, lack of shims, misalignment of rail, etc.).

The ELR module behaves abnormally (multiple cycles, clicking, delayed retraction, etc.):

o Remove cover and confirm that LED is blinking steadily when power is applied. If not, refer to LED signaling.

Note: When configured in POWER MODE, power is released to lock the device (LED will not blink when power is released).

For applications using automatic operator(s): Door(s) fail to unlock before doors begin to open:

o Adjust timing of operator to allow 750ms for the ELR module to fully retract.

For additional installation assistance, please contact 1-800-810-WIRE (9473). When calling, please provide the following information to

improve our service (provide what you can):

o Your name and contact number.

o Sargent 7000 Multi-point Device product type.

o Location and identification of the affected opening (e.g., site, building, and door number).

o SARGENT order number (located on product box), if available.

o Power supply manufacturer and rated output (i.e., voltage and current).

o Method of operation (e.g., POWER MODE).

o The number of devices connected to the power supply.

o Symptoms of problem (i.e., observed behavior).