Adjustments
Cleaning Out Meters
NOTE: Shut off sliding seed tubes before at-
tempting to clean out seed meters.
For seed meter clean out:
1.
Position tarp or buckets under the opener(s)
whose meter(s) you will be cleaning out.
Refer to Figure 45
2.
Remove retaining clip and pull pin.
Refer to Figure 46
3.
Pull up on meter clean out door to open.
4.
When meter is empty, push meter clean out
door back to its original position to close.
NOTE: You may need to shake the clean out
door a little before closing to make sure all
seeds fall out.
Refer to Figure 47
5.
Replace pin and retaining clip.
Figure 45
Meter clean out
22856
Retaining clip
Clean out door
Figure 46
Meter clean out door
22857
Clean out door
Figure 47
Meter Clean Out
22858