Operating instructions, Tractor hookup – Great Plains 2525P Operator Manual User Manual

Page 79

Advertising
background image

4/23/2010

118-915M

77

Veris Drive Operating Instructions

Operating Instructions

Drive Operational Requirements:

Hydraulic System:

Closed center, pressure compensated or

load sensed systems only

Drive will not operate on open-centered hy-

draulic systems

Minimum Hyd. Pressure: 2250 psi

Maximum Hyd. Pressure: 3000 psi

Maximum Required Flow:

25’

8.5 gpm

Electrical System:

Voltage:

12 volt DC

Amperage:

4 amperes

Tractor Hookup

Hydraulics:

1.

Connect pressure hose (P) to retraction outlet

2.

Connect motor return hose (T) to motor return
port (if available) or to extension outlet.

3.

Set flow rate at maximum required flow (8.5
gpm).

4.

If tractor is equipped with electro-hydraulic
valves, set timer to “constant” flow.

Electrical:
Refer to Figure 101

1.

Power must be connected directly to the bat-
tery using power port adapter (PN: 19729).
Make sure the eyelets are properly connected
(Red to positive and Black to negative). Con-
nect female socket to the power port adapter.

Figure 101

22714

Advertising
This manual is related to the following products: