2525P and 2520P
118-915M
4/23/2010
84
Refer to Figure 117
16. Enter the actual amount metered using the
Up/Down arrow keys. Press Function key to
advance to next window.
Refer to Figure 118
17. A New calibration number is suggested,
along with the Old calibration number.
Refer to Figure 119
18. Press Function key to advance to window
shown.
19. If you wish to keep the Old number, perhaps
to re-run the calibration procedure, press the
Down arrow key. If you want to accept the
New calibration number, press the Up arrow
key.
Figure 117
Figure 118
Figure 119
22730