Veris Drive Operating Instructions

Console Functions

Refer to Figure 102

The use of each key is as follows:

On/VR key—turns drive system on. Press

twice for VR mode. Note: Engage key must
also be pressed to start drive operation.

Off key: used to shut off Console.

Function key: used in calibration mode and to

program Console for VR recipes.

Up/down arrow keys: used to change rates

manually, to set calibration numbers, and VR
controller options.

Engage key: press to start drive.

NOTE: Drive will not run unless light above key is
illuminated.

NOTE: Figure 104 shows Main Operating Screen
in manual mode.

Calibration

Refer to Figure 103

1.

Turn on Controller Console by pressing On/
VR key. Green light above On/VR key will illu-
minate when power is on. Adjust desired
planting rate by using the Up/Down arrow
keys to change the Set rate.

2.

Set the desired Rate by using the Up/Down
arrow keys.

Refer to Figure 104

3.

Press Function key until Calibration Number
window appears. Select drive calibration
number based on row spacing and metering
wheel, from chart on page 86. Use Up/Down
arrow keys to set Calibration number.

Figure 102

Figure 103

Figure 104