Troubleshooting gps-based seed- ing with pf3000 – Great Plains 2525P Operator Manual User Manual

Page 95

Advertising
background image

4/23/2010

118-915M

93

Veris Drive Operating Instructions

Troubleshooting GPS-based seed-
ing with PF3000

1.

No Target Rate appears on the PF3000

has field been selected? Select target file (see

PF3000 Settings, Step 4)

check recipe to verify that it is valid

if recipe calls for zero rate as the default, do you

have GPS signal, or are you outside of field?

2.

No Actual Rate appears on the PF3000.

actual rate cannot be logged using the PF3000

with the Great Plains Precision Population Con-
troller.

3.

Target Rate appears on PF3000 but not on GP
Controller Console.

make sure GP Controller Console is set to VR

Mode (see Figure 120 page 86)

double-check all cable connections

check Nominal rates on both the PF3000 (PF3000

Settings, Step 5), and on the GP Controller Con-
sole (GP Settings, Step 2) These must be set to
the same number.

4.

Rates on GP Controller Console and on PF3000
do not match.

check Nominal rates on both the PF3000 (PF3000

Settings, Step 5), and on the GP Controller Con-
sole (GP Settings, Step 2) These must be set to
the same number.

Re-check GP calibration number, with metering

wheel and row spacing.

The recipe rates from the PF3000 are in 4% incre-

ments. If the two rates are within this 4% range,
the units are operating normally.

Check the target conversion number (PF3000

Settings, Step 6). If the recipe requires a target
conversion number, i.e. the recipe is for 25 which
means 25,000 seeds/acre, the target conversion
number will be 1000. In this case the Nominal
Rate on the PF3000 and on the GP Console
should be near 25,000. See PF 3000 Settings,
Step 5 for calculating Nominal Rate.

5.

Population Monitor rate does not match GP Con-
troller Console.

Make certain that PF3000 and GP Controller Con-

sole agree. If not, see Troubleshooting step 4
above.

Re-check GP calibration number, with metering

wheel and row spacing.

Re-check planter monitor settings: calibration

number, row spacing, number of rows, swath
width, seed, etc.

When planting small size seeds and/or at high

rates, if population monitor consistently indicates
a lower population than the GP Controller Con-
sole, contact monitor manufacturer for perfor-
mance specs for that application.

Advertising