Troubleshooting gps-based seed- ing with sitemate – Great Plains 2525P Operator Manual User Manual

Page 93

Advertising
background image

4/23/2010

118-915M

91

Veris Drive Operating Instructions

Troubleshooting GPS-based Seed-
ing with SiteMate

1.

No Rx rate appears on SiteMate

has field been selected? Select VRT file (see

SiteMate Settings, Step 5)

check recipe to verify that it is valid by viewing At-

tributes for each zone in SiteMate

if recipe calls for zero rate as the default, do you

have GPS signal, or are you outside of field?

2.

Rx rate appears on SiteMate, but no Applied Rate.

make sure “Go” button on SiteMate is pressed.

(button should read “Stop” when recipe is being
sent to GP Console)

you must be planting in order for Applied Rate to

appear.

3.

Rx rate appears on SiteMate but not on GP Con-
troller Console.

make sure GP Controller Console is set to VR

Mode (see Figure 120, page 86)

double-check all cable connections

check Nominal rates on both the SiteMate (SiteM-

ate Settings, Step 4), and on the GP Controller
Console (GP Settings, Step 2) These must be set
to the same number.

4.

Rates on GP Controller Console and on SiteMate
do not match.

check Nominal rates on both the SiteMate (SiteM-

ate Settings, Step 4), and on the GP Controller
Console (GP Settings, Step 2) These must be set
to the same number.

Re-check GP calibration number, with metering

wheel and row spacing.

The recipe rates from SiteMate are in 4% incre-

ments. If the two rates are within this 4% range,
the units are operating normally.

Check the Conversion number (SiteMate Settings,

Step 2). If the recipe requires a target conversion
number, i.e. the recipe is for 25 which means
25,000 seeds/acre, the target conversion number
will be 1000. In this case the Nominal Rate in
SiteMate and the GP Console should be near
25,000. See SiteMate Settings, Step 4 for calculat-
ing Nominal Rate.

5.

Population Monitor rate does not match GP Con-
troller Console.

Make certain that SiteMate and GP Controller

Console agree. If not, see Troubleshooting step 4.

Re-check GP calibration number, with metering

wheel and row spacing.

Re-check planter monitor settings: calibration

number, row spacing, number of rows, swath
width, seed, etc.

On small seeds and/or high rates, if population

monitor consistently indicates a lower population
than the GP Controller Console, contact monitor
manufacturer for performance specs for that appli-
cation.

6.

GPS signal is not being received by SiteMate:

verify that GPS serial port (which is also the dock-

ing port) is not set to PC connection only (Start/
Settings/Communications/PC Connections-check
GPS settings in Configure/Settings/GPS settings/
COM (typically COM1, 4800 Baud, 8 data bits,
Parity None, and Stop Bits 1)

Click Data tab to view GPS details

Advertising
This manual is related to the following products: