Troubleshooting – Great Plains NTA3007HD Operator Manual User Manual

Page 104

Advertising
background image

100 NTA907HD or NTA3007HD

166-207M

04/04/2011

Troubleshooting

See also:
Down-Pressure Adjustment Indications” on page 86, and
Troubleshooting and Alarms” topic in DICKEY-john Air Cart Control manual.

Problem

Causes

Solutions

No material flow
(all rows)

Contact drive not engaged - center section
locks still in ROAD

Raise opener sub-frames. Move center
frame locks from ROAD to FIELD.

Tire problems at contact drive

Check transport and contact tire sizes and
inflation (page 145).

Broken or removed chain(s) in drive system

Check chains against “Chain Routing” on
page 155.

Removed final rate Range gear(s); for exam-
ple, single hopper operation with incorrect
meter disabled

Re-install gear(s) per chart and calibration
for affected meter.

Variable rate gearbox set to zero, or too low

Re-set gearbox per calibration.

Empty hopper

Load material.

Meter in use clogged

Clean-out meter (page 108).

Rear meter in use, but front meter box (not in
use) is clogged.

Clean-out meter (page 108).

Fan speed too low

Check pulses-per-rev setting for fan in seed
monitor (page 153). Increase fan speed to
recommended range (page 83).

Fan running backward

Reverse fan circuit hoses at hitch.

No material flow
(multiple rows)

Primary seed hose blocked

Check seed hoses for kinks, congealed
materials at low spots, nests and pests.

Tower inlet or turret blocked

No material flow
(one or two rows)

Seed tube blocked at row

Inspect and clear seed tube.

Tower port blocked for affected row

Disassemble distribution ring and clear
blockage.

False alarm - seed tube sensor discon-
nected or failed

Run monitor self-test. Swap sensor with a
working row to verify failure. Replace sensor.

Material is flowing, but
is not detected by seed
monitor

This is normal during the first few meters/feet
of planting, as it takes some time for material
to reach rows.

Lower openers 3m/10ft before planting is to
begin. Monitor does not check for blockage
during first 5 seconds.

Lift switch mis-adjusted, failed or mis-wired.

Check, adjust or replace switch (page 84).

Seed monitor disconnected at hitch

Connect seed monitor.

Planting too little
(some rows)

Partial blockage in meter chamber, seed
hoses, towers, seed tubes

Treat as blockage. See “No material flow
(multiple rows)
” on page 100 and “No
material flow (one or two rows)
” on page
100.

Advertising
This manual is related to the following products: