Auger unloading: front hopper – Great Plains NTA3007HD Operator Manual User Manual

Page 72

Advertising
background image

68 NTA907HD or NTA3007HD

166-207M

04/04/2011

Refer to Figure 75
14. With the meter area clear, briefly operate auger to

verify which direction of handle movement lifts mate-
rial. Have the auger operator stand ready.

15. Have a second person open the Clean-Out door

and exit the area.

16. As soon as the door operator is clear of the auger,

operate auger control valve for material lift.

17. When flow from meter stops, rotate calibration crank

until no material flows from calibration side of meter.

18. When material stops flowing into the collection bin or

vehicle, set the auger controls to center/off.

19. Shut down hydraulic circuit for auger. Withdraw and

store auger (page 53).

20. If the drill will not be used again for an extended

period, complete the steps at Problem Clean-Outs
on page 109.

21. Wipe down doors and bottom of meter.

22. Close doors. For temporary parking or transport,

fully close doors. For storage, close doors only until
elastomer seals begin to touch meter housing, so
that condensation can drain. Do not leave doors
open enough for pest entry.

Auger Unloading: Front Hopper

The on-board auger is not designed for routine use as an
unloading aid at the front hopper. With the polymer inlet
hopper installed, the inlet end of the auger does not fit
under the front meter. Additionally, the outlet end of the
auger may be too low for your collection bin or vehicle.

Great Plains recommends:

• planning operations to exhaust materials in the front

hopper (or use only the rear hopper for single-hopper
tasks), or;

use the non-auger unloading procedure (page 65) for

the front hopper.

Removing the polymer inlet hopper from the auger
allows the auger to be swung under the front hopper
meter. However, without the inlet hopper, the auger inlet
will not catch all the falling material.

The loose inlet hopper can be placed under the auger
inlet to catch the excess, and divert some of it to the inlet.

Unload the rear hopper first. Then use the same steps as
for unloading the rear hopper, with these changes:

7a. Before step 7(b) on page 66, remove the auger inlet
hopper.

7c. After step 7(b), maneuver inlet hopper under inlet.

Null4:

Figure 76

Meter Doors Open

26341

2

1

2

Null4:

Auger Unload: Hydraulic Circuit Operation

Lift

Fan,

Auger

Fold, Tilt,

Marker

Transport

Hooks

Neutral

Float or

Neutral

Neutral

Neutral

Advertising