Implement lift switch adjustment, Planting depth, Implement lift switch adjustment planting depth – Great Plains NTA3007HD Operator Manual User Manual

Page 88

Advertising
background image

84 NTA907HD or NTA3007HD

166-207M

04/04/2011

Implement Lift Switch Adjustment

Refer to Figure 89 and Figure 90
An implement lift switch

on the drill turns seed meter-

ing off when the implement is raised. To adjust the switch
activation height, first locate the lift switch on the imple-
ment (center section, right parallel arms).

Do not place any part of body under implement while making
adjustments.

Wings must be tilted down, and may be folded forward to
ease access to the switch. Lower the openers until at a
height where seeding should start (usually just above
ground). Turn off the tractor and remove the key.
Securely support center section sub-frame at this height
with jack stands or blocks.

Loosen switch pivot screws

. Adjust switch angle so

that toggle

is level, or slightly tilted up to the rear.

Loosen bracket bolts

and slide switch

up or down

until the flexible switch toggle

is just past the point at

which the switch is activated (flexible switch toggle
deflected down).

Note: The implement lift switch has three wires (black,

red and green). In order for the switch to work prop-
erly, the correct two leads must be connected to the
lift switch extension cable.

The extension cable black lead always connects to
the switch black wire.

The extension cable red lead must connect to the
switch red wire.

Planting Depth

Seed placement depth is affected by:

• soil conditions

, which can require adjustments to all

of the following;

• press wheel T-handle

setting (page 98),

which controls opener disk depth relative to press
wheels;

• (optional) coulter depth

(page 92), which prepares

the soil ahead of the opener disks;

• hydraulic

down-force (page 85) and

row unit spring

down-force (page 95),

which needs to be high enough for disks to open a fur-
row, but not so high that press wheels run deep or
openers tilt forward and run too deep; and,

• opener

wear (page 95), which over time can cause

established T-handle settings to be too shallow.

Null4:

Figure 89

Lift Switch Location

29475

2

1

2

3

Null4:

Figure 90

Lift Switch Adjustment

29436

1

2

3

4

4

1

4

Null4:

Figure 91

07HD Coulter and Row Unit

29419

1

2

3

4

5

6

1

2

3

4

5

6

Advertising