Monitor setup data – Great Plains NTA3007HD Operator Manual User Manual

Page 157

Advertising
background image

Appendix A - Reference Information 153

04/04/2011

166-207M

Monitor Setup Data

Seed monitor setup is normally performed using the
Quick Start Guide (QSG, part number 110011516). If the
QSG is not available, the table at right, plus the Specifi-
cations and Capacities data starting on page 144, pro-
vide the required and key factory default settings.

Notes:

MetaData: End of Seed Hose Port Maps

a

Required Value:
Do not change.

b

Factory Default:
An approximate initial value. Refine with material
data and/or calibration.

c

Type:
Change to “GRAN...CONTROL” if optional variable
rate seeding is installed.

Note NTA907HD NTA3007HD

Row Setup

Model: NTA..-3610

a

9 sensors/WSMB

Model: NTA..-4875

a

12 sensors/WSMB

Model: NTA..-6006

a

15 sensors/WSMB

Ground Speed

Source

a

Digital Frequency

Constant

b

38416

46837

Alarm Delay (generally)

b

5 sec

Accessory Setup

Hopper Level Logic

a

ACTIVE LO

Front Hopper is no.

a

1

# of RPM sensors

a

1

Fan RPM Constant

a

3 pulses/rev

RPM filter

a

50 %

# of Pressure Sensors

a

2

High Alarm

b

8.6 kpa

20 oz/in3

Low Alarm

b

1.7 kpa

4 oz/in3

Pressure Filter

a

50

Material Setup

Type (for seeding)

c

GRAN SEED MONITOR

Type (for fertilizer)

c

GRAN FERT MONITOR

Total # of Towers

a

4

Material Defaults

Seed

b

0.77 kg/l

60 lbs/bu

Fertilizer

b

0.96 kg/l

60 lbs/ft3

Calibration Constants

Seeding

b

3031

85831

Fertilizer

b

2931

82996

Channel Setup

Input Filter

a

50%

Sensor Constant

a

360 pulses/rev

Gear Ratio

a

1

Advertising