Find your chart and rate, Dual hopper considerations, High rate flute considerations – Great Plains NTA3007HD Operator Manual User Manual

Page 77: Adjustment for dual metering / high rate flutes, Chartrate fieldrate lookupfactor, Calrate fieldrate twinfactor ч, Adjustments 73, Target rate adjustments, 2 stars (std.), 3 stars

Advertising
background image

Adjustments 73

04/04/2011

166-207M

Find Your Chart and Rate

Standard “2 star” rates are in the main section of the
Seed Rate manual. “3 star” and “4 star” rates are in the
Appendix.

If you are planning to operate both hoppers, perform the
setup steps separately for each hopper, as the configura-
tions (including stars) may be completely different.

1.

Confirm that the chart is for the material and star
configuration you have.

2.

Find your target population or application rate.

Note: If you have a choice of charts, for most consistent

results, pick one that results in a variable rate gear-
box value between 30 and 70.

Dual Hopper Considerations
If you are applying the same material from both hoppers,
what chart rate to start with depends on whether you will
run both meters simultaneously, or sequentially (run one,
then the other).

The charts do not account for “twin” hopper operation. If
both hoppers are metering the same material, at the
same rate, and at the same time, the output is twice the
chart rate. If run sequentially, or metering different mate-
rials at the same time, treat them as single-hopper oper-
ation.

High Rate Flute Considerations

“High Rate” charts are provided for some seeds, but the
charts do not cover all possible combinations of high-rate
flutes. You can use any standard-rate single-hopper
chart.

Adjustment for Dual Metering / High Rate Flutes
To find the initial chart rate for dual hopper and/or alter-
nate flutes:

To find the rate to check at calibration:

Null4:

Great Plains Man

ufactur

ing, Inc.

Seed Rates

27

04/23/2010

167-085B

Wheat (2 Star

s)

Higher r

ate Wheat char

ts, requir

ing optional flutes

, are on page

37 and page

38

Notes:

Stated

seed

density

is measured,

and not

customar

y commodity

call

weight. If y

our seed has a significantly diff

erent density

, see “

Den-

sity Adjustment

” on page

30.

Table rates are f

or application from a single hopper at a time

(whether or not both are loaded with the same mater

ial). F

or appli-

cation of the same mater

ial from both hoppers sim

ultaneously

, do

not use the target r

ate data. First divide the target r

ate b

y two, and

use the setting f

or that half r

ate. Use that target r

ate for calibr

ating

each meter

.

Final Drive Range Gear

s

Stars Per Outlet

Seed Density

Remarks:

l

e

h

s

u

b

r

e

p

s

d

n

u

o

p

5

.

1

6

2

e

g

n

a

R

h

g

i

H

See table footnotes

.

54T Driving; 17T Driven

(standard)

0.79 kg/liter

Seed Rate

e

t

a

R

d

e

e

S

e

t

a

R

d

e

e

S

a

h

/

g

k

c

a

/

s

b

l

a

h

/

g

k

c

a

/

s

b

l

a

h

/

g

k

c

a

/

s

b

l

0

0

0

-

100.2

112.3

46

77955

238.5

267.3

73

81929

16.4

18.4

20

75699

104.7

117.3

47

77990

243.7

273.1

74

82307

18.4

20.6

21

75902

109.2

122.4

48

78027

248.8

278.9

75

82712

20.5

23.0

22

76092

113.9

127.6

49

78067

253.8

284.5

76

83146

22.7

25.4

23

76268

118.5

132.9

50

78110

258.8

290.1

77

83610

25.0

28.0

24

76431

123.3

138.2

51

78159

263.6

295.5

78

84106

27.4

30.7

25

76582

128.2

143.7

52

78212

268.4

300.8

79

84636

29.9

33.5

26

76722

133.1

149.2

53

78272

273.0

306.1

80

85202

32.5

36.4

27

76850

138.0

154.7

54

78338

277.6

311.1

81

85806

35.2

39.5

28

76967

143.1

160.4

55

78411

281.9

316.0

82

86451

38.0

42.6

29

77074

148.2

166.1

56

78493

286.2

320.8

83

87138

40.9

45.9

30

77172

153.3

171.8

57

78583

290.2

325.3

84

87871

43.9

49.2

31

77260

158.5

177.6

58

78684

294.1

329.7

85

88653

47.0

52.7

32

77341

163.7

183.5

59

78794

297.8

333.9

86

89486

50.2

56.3

33

77413

169.0

189.4

60

78916

301.4

337.8

87

90374

53.5

60.0

34

77479

174.3

195.4

61

79050

304.6

341.5

88

91322

56.9

63.7

35

77538

179.6

201.3

62

79197

307.7

344.9

89

92332

60.4

67.6

36

77591

185.0

207.4

63

79357

310.5

348.1

90

93410

63.9

71.7

37

77640

190.4

213.4

64

79532

313.1

350.9

91

94560

67.6

75.8

38

77683

195.8

219.4

65

79723

315.4

353.5

92

95789

71.4

80.0

39

77723

201.2

225.5

66

79930

317.4

355.8

93

97102

75.2

84.3

40

77760

206.5

231.5

67

80155

319.1

357.7

94

98506

79.2

88.7

41

77795

211.9

237.6

68

80398

320.5

359.2

95

100008

83.2

93.3

42

77828

217.3

243.6

69

80660

321.5

360.4

96

101617

87.3

97.9

43

77859

222.7

249.6

70

80943

322.2

361.1

97

103342

91.5

102.6

44

77891

228.0

255.5

71

81248

322.5

361.5

98

105194

95.8

107.4

45

77923

233.3

261.5

72

81576

322.4

361.4

99

107184

Wheat

(2 St

ars)

31308

Gearbox
Setti

ng

Cal.

Const.

Gearbox

Setti

ng

Cal.

Const.

Gearbox
Setting

Cal.

Const.

Target Rate Adjustments

Hoppers for This Material

Single or

Sequential

Dual

Simultaneous

2 Stars
(std.)

Chart would be 1x rate

LookupFactor = 1.0

TwinFactor = 1.0

Chart would be 2x rate

LookupFactor = 0.5

TwinFactor = 0.5

3 Stars

Chart would be 1.5x rate

LookupFactor = 0.67

TwinFactor = 1.0

Chart would be 3x rate

LookupFactor = 0.33

TwinFactor = 0.5

4 Stars

Chart would be 2x rate

LookupFactor = 0.5

TwinFactor = 1.0

Chart would be 4x rate

LookupFactor = 0.25

TwinFactor = 0.5

Null4:

For Example:
Drill: NTA907HD-4875
Crop: Barley (no high rate flute chart available)
Field rate: 500 kg/ha (above 2 flute chart coverage)
Flutes: 3 star
Metering: simultaneous dual hopper

165 = 500 x 0.33

Lookup the settings for 165 kg/ha

ChartRate

FieldRate

LookupFactor

×

=

Null4:

Continuing the example:
Field rate: 500 kg/ha

250 = 500 x 0.5

Calibrate each meter to 250 kg/ha

CalRate

FieldRate

TwinFactor

Ч

=

Advertising