Folding: tilt wings up – Great Plains NTA3007HD Operator Manual User Manual

Page 42

Advertising
background image

38 NTA907HD or NTA3007HD

166-207M

04/04/2011

13. When the wings are fully folded, stop cylinder exten-

sion and hold wings at folded.

Null4:

14. Disable the fold solenoid valve by setting CFM switch

Fold to off.

Null4:

Folding: Tilt Wings Up

Wing folding must be complete (step 9 through step 14
starting on page 37) before performing the next steps.

Tilt-Up After Fold and Before Hook

For smoothest operation, and to reduce risk of machine dam-
age, perform the tilt-up after fold, and before transport hook.

Null4:

Refer to Figure 39
15. On the CFM switch, enable the Tilt solenoid valve by

setting switch Tilt on.

Null4:

16. Initiate tilt-up by extending the tilt cylinders.

Null4:

Null4:

Null4:

Fold Complete: Circuit Operation

Lift

Fan,

Auger

Fold, Tilt,

Marker

Transport

Hooks

Neutral

Neutral

Neutral

Neutral

Null4:

Figure 37

CFM Fold Complete

29380

Null4:

Figure 38

Tilt Up Progression

29397

Null4:

Figure 39

CFM Tilt-Up Enable

29380

Null4:

Tilt-Up Initiate: Hydraulic Circuit Operation

Lift

Fan,

Auger

Fold, Tilt,

Marker

Transport

Hooks

Neutral

Neutral

Extend

Neutral