1 criterion tgx and criterion tgx stain-free gels, 1 criterion, And criterion – Bio-Rad Criterion™ TBE-Urea Precast Gels User Manual

Page 14: Tgx stain-free, Gels

Advertising
background image

8

Technical Support: 1-800-4BIORAD • 1-800-424-6723 • www.bio-rad.com

Table 3.1. Criterion precast gels for SDS-PAGE.

Gel Formulation

Gels

Description

TGX (Laemmli-like)

Criterion

TGX

Laemmli-like, extended shelf life gels

Criterion

TGX Stain-Free

Laemmli-like, extended shelf life gels with trihalo compounds for rapid

fluorescence detection

Tris-HCl (Laemmli)

Criterion Tris-HCl

Tris-HCl Laemmli gels

Criterion Stain Free

Tris-HCl Laemmli gels with trihalo compounds for rapid fluorescence

detection

Bis-Tris Criterion

XT Bis-Tris

Based on a Bis-Tris HCl buffer system (pH 6.4); use these gels with

Criterion XT MES buffer for optimum resolution of small proteins

Bis-Tris

Criterion XT Bis-Tris

Based on a Bis-Tris HCl buffer system (pH 6.4); use these gels with

Criterion XT MOPS buffer for optimum resolution of midsized proteins

Tris-acetate

Criterion XT Tris-acetate

Based on a Tris-acetate buffer system (pH 7.0)

3.2.1 Criterion TGX and Criterion TGX Stain-Free Gels
Criterion TGX (Tris-Glycine eXtended shelf life) gels are Laemmli-like gels with a proprietary modification
that extends their shelf life to 12 months and enhances separation characteristics relative to conventional
gel types. The TGX formulation yields Laemmli-like separation patterns with short run times and
exceptionally straight lanes and sharp bands. TGX gels offer excellent staining quality, greater transfer
efficiency, and molecular weight estimation without the need for special, expensive buffers.

These gels are run using standard Laemmli sample buffer and Tris/glycine/SDS running buffer. Two
types of TGX formulations are available:

n

Criterion TGX — Laemmli-like, extended shelf life gels

n

Criterion TGX Stain-Free — Laemmli-like, extended shelf life gels with trihalo compounds

that allow rapid fluorescent detection of proteins with the Criterion Stain Free system,
eliminating staining and destaining steps for faster results (see Chapter 5 for more details)

Gel Composition

Crosslinker

2.6% C

Stacking gel

4% T, 2.6% C

Shelf life

~12 months at 2–8°C; expiration date is printed on each cassette

Gel Percentage

Optimum Separation Range

7.5%

40–200 kD

10%

30–150 kD

12%

20–120 kD

18%

10–50 kD

4–15%

20–250 kD

4–20%

10–200 kD

8–16%

20–120 kD

10–20%

10–100 kD

Any kD

1

10–200 kD

1

Any kD is a unique single-percentage formulation that provides a broad separation range and short running time.

Criterion Precast Gels