CAUTION:

Enclosure loss protection is not guaranteed if a physical disk has

already failed in the disk group. In this situation, losing access to an expansion
enclosure and consequently another physical disk in the disk group causes a
double physical disk failure and loss of data.

Enclosure loss protection is achieved when you create a disk group where all

of the physical disks that comprise the disk group are located in different

expansion enclosures. This distinction depends on the RAID level. If you

choose to create a disk group by using the Automatic method, the software

attempts to choose physical disks that provide enclosure loss protection. If

you choose to create a disk group by using the Manual method, you must use

the criteria specified in Table 10-2.

Table 10-2. Criteria for Enclosure Loss Protection

RAID Level

Criteria for Enclosure Loss Protection

RAID level 5

or RAID level

6

Ensure that all the physical disks in the disk group are located in

different expansion enclosures.
Because a RAID level 5 requires a minimum of 3 physical disks,

enclosure loss protection cannot be achieved if your storage array has

less than 3 expansion enclosures.
Because a RAID level 6 requires a minimum of 5 physical disks,

enclosure loss protections cannot be achieved if your storage array has

less than 5 expansion enclosures.