Configuration: Disk Groups and Virtual Disks

a

Change the RAID controller module ownership of a virtual disk—Go

to step 2.

b

Change the RAID controller module ownership of a disk group—Go

to step 3.

2 To change the RAID controller module ownership of a virtual disk,

perform these steps:

a

Select the Logical tab.

b

Select the virtual disk.

c

Select Virtual Disk Change Ownership/Preferred Path.

Alternatively, you can right-click the virtual disk and select

Change

Ownership/Preferred Path from the pop-up menu.

d

Select the RAID controller module.

CAUTION:

Possible loss of data access – If you do not use a multi-path driver,

shut down any host applications that are currently using the virtual disk. This
action prevents application errors when the I/O path changes.
e

Click Yes.

The ownership of the virtual disk is changed. I/O to the virtual disk is now

directed through this I/O path. You are finished with this procedure.

NOTE:

The virtual disk may not use the new I/O path until the multi-path driver

reconfigures and recognizes the new path. This action usually takes less than

5 minutes.

3 To change the RAID controller module ownership of a disk group, perform

these steps:

a

Select the Logical tab.

b

Select the disk group.

c

Select Disk Group Change Ownership/Preferred Path.

Alternatively, you can right-click the disk group and select

Change

Ownership/Preferred Path from the pop-up menu.

d

Select the RAID controller module.

CAUTION:

Possible loss of data access– Changing ownership at the disk group

level causes every virtual disk in that disk group to transfer to the other RAID
controller module and use the new I/O path. If you do not want to set every virtual
disk to the new path, change ownership at the virtual disk level instead.